Maintenance and maintenance of folding mask machine

发布日期:2019-09-18 17:11
share it:
  The maintenance and overhaul of the folding mask machine is very important. The maintenance of the mask machine can bring better work to the mask machine. It is safer and more efficient. So what should we do when we maintain the mask machine? If the mask machine is not repaired, the accuracy of the mask machine will decrease, and the maintenance probability of the mask machine will increase. Generally, the maintenance of the mask machine is differential: pneumatic system, ultrasonic system, transmission system, electrical system, appearance In terms of maintenance, it is necessary to perform a power outage during the maintenance process.

First, the pneumatic system:

The air filter cup of the
mask equipment needs to check whether there is water release and the water compressor should be drained. In the area with high humidity, the air compressor should be drained every day to check whether all the air cylinders have air leakage. The cylinder magnetic anti-sensor Orientation and whether it is normal.

Second, the ultrasound system

Check whether the ultrasonic mask machine system is kept clean, especially the ultrasonic electric box, the vibrator (transducer), the welding head need to be dry and clean, and there is no water. It is necessary to connect the wire to see the wear of the ultrasonic welding head. Pay attention to the scale of the voltmeter and ammeter pointer on the ultrasonic box.

Third, the transmission system

The transmission system includes components such as motors, gears, reducers, sprockets, chains, conveyor belts, etc. We have to check whether the motor has dust and other things that affect the heat dissipation, whether the gears and sprockets are oiled, and if there are attachments, then Clean up, chain tension is not suitable for the presence or absence of foreign matter is not cleaned, the connection screws between the transmission parts are not loose, the lubricating oil of the reducer is not enough, usually the machine needs to be replaced once in 1000-1500 hours .

Fourth, the electrical system


Check whether the connector of the mask machine equipment is loose, whether the main power cord, branch signal line, etc. are worn and aging. Will the electrical equipment loosen the dry environment in the electrical box, and the exhaust fan is normal? Work and so on.

Fifth, the appearance

The mask is used to wear on the face, and the medical mask needs to enter the operating room. Therefore, the production of the mask must require the neat cleaning of the mask machine. Every day after work, people need to arrange the personnel for the mask machine after the power off. The work surface and the plate containing the mask are cleaned. Note that it is not possible to wash with water. Use a non-toxic and volatile cleaning solution such as alcohol to clean the equipment.

Sixth, other

The equipment should not be attached with corrosive liquids and objects. The sweat can easily lead to rusting of the equipment parts. If the equipment does not work for a long time, it is necessary to apply anti-rust oil to the transmission system of the mask and the parts that are easy to rust.